山東機(jī)箱機(jī)柜:服務(wù)器機(jī)柜的尺寸你了解多少?
發(fā)布時(shí)間:2025-08-23 來(lái)源:http://www.143318.com/ 瀏覽量:
在托管、購(gòu)買服務(wù)器或者租用、使用機(jī)柜的時(shí)候,有時(shí)會(huì)聽到1U、2U、4U或者42U等類似這樣子的名詞。而這些名詞又代表什么意思呢?跟著快網(wǎng)小編一起來(lái)了解一下吧!
When hosting, purchasing servers, or renting or using server cabinets, sometimes we hear terms like 1U, 2U, 4U, or 42U. And what do these nouns represent? Follow the Quick Net editor to learn more!
關(guān)于“U”的單位U是一種表示服務(wù)器外部尺寸的單位,是unit的縮略語(yǔ)。規(guī)定了服務(wù)器的尺寸,可以使服務(wù)器以一定的尺寸放在機(jī)架上。機(jī)架上有固定服務(wù)器的螺孔,以便它能與服務(wù)器的螺孔對(duì)上號(hào),再用螺絲加以固定好,這樣子可以方便安裝每一部服務(wù)器所需要的空間。
Regarding the unit of 'U', U is a unit that represents the external dimensions of a server and is an abbreviation for 'unit'. The size of the server is specified, which allows the server to be placed on the rack with a certain size. There are screw holes on the rack to fix the server, so that it can match the screw holes of the server, and then be fixed with screws to facilitate the installation of the required space for each server.
1U 2U 4U 服務(wù)器服務(wù)器規(guī)定的尺寸是服務(wù)器的寬(48.26cm=19英寸)與高(4.445cm的倍數(shù)),厚度(高度))以4.445cm為基本單位。在機(jī)架式服務(wù)器尺寸當(dāng)中,常見的就是1U服務(wù)器、2U服務(wù)器、4U服務(wù)器,這些服務(wù)器的尺寸是:1U=4.445厘米,2U=4.445*2=8.89厘米,4U=4.445*4=17.78厘米。在實(shí)際使用當(dāng)中,1U或者2U服務(wù)器是經(jīng)常使用的。因?yàn)榉?wù)商是根據(jù)服務(wù)器占用空間來(lái)計(jì)算費(fèi)用的,所以采用1U服務(wù)器是節(jié)省空間的和的,但是1U服務(wù)器的擴(kuò)展性不如2U服務(wù)器的好。1U的硬盤數(shù)多可以插4個(gè)3.5寸,2U可以插8個(gè)3.5寸甚更多,另外PCI的插槽數(shù)目也不同,1U多2個(gè),2U的可以到6個(gè)。
The dimensions specified for a 1U 2U 4U server are the width (48.26cm=19 inches) and height (multiples of 4.445cm) of the server, with thickness (height) measured in units of 4.445cm. The common sizes of rack mounted servers are 1U servers, 2U servers, and 4U servers. The dimensions of these servers are: 1U=4.445 centimeters, 2U=4.445 * 2=8.89 centimeters, and 4U=4.445 * 4=17.78 centimeters. In practical use, 1U or 2U servers are the most commonly used. Because service providers calculate fees based on server space occupancy, using a 1U server is the most space saving and cost-effective option. However, the scalability of a 1U server is not as good as that of a 2U server. A 1U hard drive can accommodate up to 4 3.5-inch hard drives, while a 2U can accommodate 8 3.5-inch or even more. Additionally, the number of PCI slots varies, with a maximum of 2 for 1U and up to 6 for 2U.
42U機(jī)柜42U機(jī)柜一般的分類是:1)按寬度分:600mm和800mm寬的42U機(jī)柜,深度有:600mm,800mm,900mm,960mm,1000mm,1100mm,1200mm等;2)按實(shí)際需求分:除了實(shí)際使用尺寸是42U之外,寬度和深度可以按照實(shí)際需求定制。一個(gè)機(jī)柜所放的服務(wù)器是有限的,42U高度的機(jī)柜并不代表著實(shí)際能夠放42個(gè)1U服務(wù)器。放了服務(wù)器之后還要留散熱和挪動(dòng)的空間,一些走線的空間,還有放交換機(jī)、防火墻、顯示器等其他設(shè)備的空間。所以一個(gè)42U機(jī)柜能放多少服務(wù)器,需要根據(jù)具體的設(shè)備來(lái)計(jì)算。那么問(wèn)題來(lái)了,一個(gè)機(jī)柜一般部署多少臺(tái)服務(wù)器設(shè)備?一個(gè)機(jī)柜部署的服務(wù)器數(shù)量,要考慮很多參數(shù),比如服務(wù)器的體積、功耗、發(fā)熱量等物理參數(shù),還需要考慮機(jī)柜的供電、冷卻、承重等參數(shù),如何確定能部署多少臺(tái)服務(wù)器,做決定時(shí)可以參考一下關(guān)鍵參數(shù):1)預(yù)留:每個(gè)設(shè)備間預(yù)留1U以便散熱,預(yù)留交換機(jī)位置,考慮PDU位置;2)一般提供冗余10KW電源,靜態(tài)承載能力不小于1200kg(根據(jù)機(jī)房建設(shè)參數(shù)確定)3)不超電的前提下,一個(gè)機(jī)柜累計(jì)設(shè)備U數(shù),一般不超過(guò)26U一個(gè)機(jī)柜,全1U設(shè)備部署數(shù)量一般不超過(guò)16臺(tái),全2U設(shè)備一般不超過(guò)12臺(tái),全4U設(shè)備一般4到7臺(tái)。
The general classification of 42U cabinets is: 1) Divided by width: 600mm and 800mm wide 42U cabinets, with depths of 600mm, 800mm, 900mm, 960mm, 1000mm, 1100mm, 1200mm, etc; 2) According to actual needs: In addition to the actual size of 42U, the width and depth can be customized according to actual needs. The number of servers that can be placed in one cabinet is limited, and a cabinet with a height of 42U does not necessarily mean that 42 1U servers can actually be placed. After installing the server, there should be space for heat dissipation and relocation, some wiring space, and space for other devices such as switches, firewalls, and displays. So how many servers can be placed in a 42U cabinet needs to be calculated based on the specific equipment. So the question is, how many server devices are usually deployed in one cabinet? The number of servers deployed in a cabinet needs to consider many parameters, such as physical parameters such as server volume, power consumption, heat generation, as well as parameters such as power supply, cooling, and load-bearing capacity of the cabinet. When deciding how many servers can be deployed, key parameters can be referred to: 1) Reservation: Reserve 1U between each device for heat dissipation, reserve switch positions, and consider PDU positions; 2) Generally, a redundant 10KW power supply is provided, with a static carrying capacity of not less than 1200kg (determined according to the construction parameters of the computer room). 3) Under the premise of not exceeding the power limit, the cumulative number of equipment U in a cabinet generally does not exceed 26U per cabinet. The deployment of all 1U equipment generally does not exceed 16 units, all 2U equipment generally does not exceed 12 units, and all 4U equipment generally ranges from 4 to 7 units.
本文由 山東機(jī)箱機(jī)柜 友情奉獻(xiàn).更多有關(guān)的知識(shí)請(qǐng)點(diǎn)擊 http://www.143318.com/ 真誠(chéng)的態(tài)度.為您提供為的服務(wù).更多有關(guān)的知識(shí)我們將會(huì)陸續(xù)向大家奉獻(xiàn).敬請(qǐng)期待.
This article is a friendly contribution from Shandong Chassis Cabinet For more related knowledge, please click http://www.143318.com/ Sincere attitude To provide you with comprehensive services We will gradually contribute more relevant knowledge to everyone Coming soon.